South Carolina utilizes the BAC DataMaster breath test machine to measure the blood alcohol content of a suspect arrested for driving under the influence. The BAC DataMaster is a product of National Patent Analytical Systems, Inc. (NPAS) located in Mansfield, Ohio.

These DUI breath test devices require regular maintenance, and a proper environment for testing administration. The BAC DataMaster is part computer, and uses an archaic LED display. If the alcohol detecting machine is not functioning properly or if the testing environment is corrupted, then the BAC DataMaster will report an error message. Below is a list of these messages.

1. Ambient Failure: The machine is unable to purge itself. The machine operator is required to check the testing room for excessive odors of alcohol or chemical odors. The operator must ensure the breath test tube is warm, and that the tube is not placed near the machine’s exit port.

2. System Will Not Zero: The operator must ensure the breath test tube is warm and is not placed near the machine’s exit port.

3. Invalid Sample: This warning is triggered by the presence of mouth alcohol, the subject is not providing a proper sample or the instrument is out of adjustment. The operator must conduct another mouth check and wait for the prescribed 15 minutes.

This error can really put the DUI suspect in hot water. If the error persists and the officer believes the DUI suspect is playing games and not cooperating, then the officer will mark the suspect as a refusal. This ratchets up the mandatory DUI penalties, and greatly increases the driver’s license suspension.

4. Radio Interference: RFI is being detected by the BAC DataMaster. The operator of the machine must determine the cause of the RFI and eliminate the source.

5. Printer Error: The BAC DataMaster will print a breath ticket showing the breath test results. The Printer Error indicates a paper jam or print malfunction.

6. Calibration Error: These machines require calibration and this error indicates the calibration could not be verified. The operator need only restart the test.

If the error messages above persist, then the operator must tag the machine “out of service” and contact the Washington State Patrol Breath Test Section.

Some other errors will indicate the machine will not run unless a member of the Breath Test Section services the device. Those errors are:

  1. Fatal Systems Error
  2. Not Calibrated
  3. Temperature High
  4. Temperature Low
  5. Pump Error
  6. Ram Error

The BAC Data Master makes many assumptions about a person and has a wide range for errors in breath sampling. Call me John Drennan at 843-352-4149 for you free case evaluation.

1 Comment

Leave a comment
Comment Information

Call Drennan Law Firm — Free Initial Consultation

Speak with a Charleston criminal lawyer today who will work with you directly, one-on-one.
Please call us at 843-352-4149 or email us to schedule a meeting or for prompt legal assistance.

Email Us 24/7 For Fast Answers

Bold labels are required.

Contact Information
disclaimer.

The use of the Internet or this form for communication with the firm or any individual member of the firm does not establish an attorney-client relationship. Confidential or time-sensitive information should not be sent through this form.

close

Privacy Policy

Main Office
1350 Chuck Dawley Blvd
Mt. Pleasant, SC 29464

Toll Free: 888-722-6179
Phone: 843-352-4149
Fax: 843-606-2971
Mt. Pleasant Law Office Map

Branch Office
Local: 843-225-2384
Toll Free: 888-722-6179